AI server power consumption: how many kilowatts local AI uses, what it costs, heat and noise

2 min read9 sources

AI server power consumption is not the biggest cost, but it is the one people forget until the first bill. Below is the power draw of real hardware from manufacturer data, a monthly formula and what to do with the heat.

On this page · 4 sections

Power draw from manufacturer data

RTX 4090: 450 W. RTX 5090: 575 W. RTX PRO 6000: 600 W. A100 PCIe: 300 W. H100 SXM: up to 700 W, H100 NVL: 350–400 W. Mac Studio M4 Max: 145 W maximum, 6 W idle. Mac Studio M3 Ultra: 270 W maximum, 9 W idle. Add the platform to the card: by our estimate, 200–400 W for a workstation and up to 1,000 W for a server with four cards.

The monthly formula

Power in kilowatts times 720 hours times the share of time under load gives kilowatt-hours; multiply by the tariff. One RTX 5090 under load around the clock: 0.575 × 720 = 414 kWh, about $39 a month at the Moscow household rate of about $0.10 per kWh. A server with four H100 cards and a 3.8 kW platform: 2,736 kWh, about $250. Real load is rarely 100%: at 40% load the bill is 2.5 times smaller, but a model held in memory keeps the card switched on: an idle RTX 4090 draws 19 W, according to the manufacturer.

Tariff

Households in Moscow pay about $0.10 per kWh from 1 January 2026. For companies the price is not regulated: it is set on the wholesale market by the hour and depends on the region, the price category, the consumption profile and the capacity. In your calculations, use the figure from your own contract; the calculator lets you enter it.

Heat and noise

All the power a server uses turns into heat: a 3.8 kW server heats a room like two or three oil heaters of 1.5–2 kW each, and an ordinary office air conditioner may not cope. A workstation with one card is audible in an office; data center cards with blower fans are not placed in offices. A data center solves both heat and noise: from $90 a month for a server up to 300 W, plus $24 for each extra 100 W. A Mac Studio with a 270 W maximum sits on a desk.

Questions and answers

Do you need a three-phase power supply?

For one or two cards, no; for a server with four data center cards and a UPS, usually yes, and it is simpler to place it in a data center.

Sources and fact-checking

Checked by the editors on 29 September 2026.

  1. NVIDIA, GeForce RTX 4090: 450 W, 24 GB (nvidia.com)
  2. NVIDIA, GeForce RTX 5090: 575 W, 32 GB GDDR7 (nvidia.com)
  3. NVIDIA, RTX PRO 6000 Blackwell: 96 GB, 600 W (nvidia.com)
  4. NVIDIA, H100: SXM 80 GB up to 700 W, NVL 94 GB 350–400 W (nvidia.com)
  5. Servermall, NVIDIA A100 40/80 GB, prices as of 29 September 2026 (servermall.ru)
  6. Apple Support, Mac Studio power consumption (support.apple.com)
  7. RusCable, Moscow electricity tariffs from 1 January 2026 (ruscable.ru)
  8. timofeev.group, how the electricity price for companies is set, 27 February 2026 (timofeev.group)
  9. HOSTKEY, colocation in Moscow, 2026 (hostkey.ru)

Found a mistake? Tell us

Publications

Contact us